Key Features:

  • Indoor/Outdoor Installation: Versatile installation options.
  • Stainless Steel Flue Included: Provides safe venting of combustion gases.
  • Battery Ignition: Uses 2 x type D batteries for ignition, eliminating the need for a pilot light.
  • Water Pressure Activation:
    • Water flow triggers a magnetic floater, activating the ignition and gas valve.
    • Operates on low water pressure (0.065 bar to 8 bar).
    • Compatible with both separate taps and mixers.
  • Sizing Based on Flow Rate:
    • Measure the water flow rate (liters per minute) at various taps.
    • Select a geyser size that matches the measured flow rate.
    • Avoid oversizing to prevent overheating and shutdown.
    • Example: 10 liters per minute flow rate requires a 9 liter per minute geyser.
  • Temperature Adjustment:
    • Start with minimum gas and maximum water flow.
    • Gradually increase the gas to achieve the desired temperature.
  • LCD Temperature Display: Shows the output water temperature.
  • Improved Design:
    • More stable ignition system, less susceptible to damage from impurities.
    • Stable water inlet pressure and flow.
    • Reduced risk of dry burn damage to the heat exchanger.
    • Reduced battery drain.
  • Zero Start unit: This means that the unit starts generating hot water only when the hot water tap is opened.

How it Works (Simplified):

  1. Water Flow: When you turn on a hot water tap, water flows through the geyser.
  2. Activation: The water pressure pushes a magnetic floater, which signals the electronic control box.
  3. Ignition: The control box triggers a spark from the battery ignition.
  4. Gas Flow: The gas solenoid valve opens, allowing gas to flow to the main burners.
  5. Heating: The burners heat the water as it passes through the heat exchanger.
  6. Temperature Control: You adjust the gas flow to control the water temperature.
  7. Display: The LCD shows the output water temperature.

Important Considerations:

  • Accurate measurement of water flow is crucial for proper sizing.
  • Correct temperature adjustment ensures efficient and safe operation.
  • The system is designed to prevent damage from low water pressure, and impurities.